VEGA 76 is a new three-phase power analyser


VEGA 76 is a new three-phase power analyser and recorder enabling the operator to use flexible heads without integrator, and therefore enjoy an indefinite recording autonomy, thanks to the electronics installed directly inside the instrument.It can perform analysis and tests on single- and three-phase systems with or without neutral.and displays in real time the values of all fundamental electrical quantities featuring the electrical installation under test showing also the trend of waveforms of voltages and currents
STANDARD ACCESSORIES

¡î
3 flexible heads 300-3000A without integrator mod. HTFLEX33
¡î measuring cables mod. KITENERGY2
¡î external power supply mod. A0050
¡î package of software and serial cable mod. TOPLINK
¡î carrying case mod. BORSA2051
¡î English instruction manual
¡î ISO9000 calibration certificate

OPTIONAL ACCESSORIES

¡î kit of straps and hooks to hang the instrument on the neck mod. CN0050
¡î case 3x1-5A/1V for connection to TA mod. HT903
¡î clamp for AC currents 200-2000A mod. HP30C2
¡î clamp for AC currents 3000A mod. HP30C3
¡î clamp 10-100-1000A mod. HT97U
¡î clamp 1-100-1000A mod. HT96U
1. ELECTRICAL SPECIFICATIONS

VOLTAGE
Range Resolution Accuracy Input Impedance
15 ¡À 310V 0.2V   ¡¾(0.5% reading+2dgt)   300K¥Ø (phase-neutral)
600k¥Ø (phase-phase)
30 ¡À 600V 0.4V

VOLTAGE ANOMALIES
Range Resolution Accuracy Input Impedance Overload protection
0.005 ¡À 0.26V 0.0001V ¡¾(0.5% reading+2 dgt) 100k¥Ø 5V
0.26 ¡À 1V 0.0004V

CURRENT
Range Resolution Accuracy Input Impedance Overload protection
0.005 ¡À 0.26V 0.0001V   ¡¾(0.5% reading+2 dgt)   100k¥Ø   5V
0.26 ¡À 1V 0.0004V

POWER
Type of measurement Range Resolution Accuracy
ACTIVE POWER 0 ¡À 999.9W
1 ¡À 999.9kW
1 ¡À 999.9MW
0.1W
0.1kW
0.1MW
        ¡¾(1.0% reading + 2 dgt)
REACTIVE POWER 1 ¡À 999.9kVAR,
1 ¡À 999.9MVAR
0.1VAR
0.1kVAR
0.1MVAR
APPARENT POWER 0 ¡À 999.9VA,
1 ¡À 999.9kVA,
1 ¡À 999.9MVA
0.1VA
0.1kVA
0.1MVA
ACTIVE ENERGY
(class 2 EN61036)
0 ¡À 999.9Wh,
1 ¡À 999.9kWh,
1 ¡À 999.9MWh
0.1Wh
0.1kWh
0.1MWh
REACTIVE ENERGY
(class 3 IEC1268)
0 ¡À 999.9VARh,
1 ¡À999.9kVARh,
1 ¡À 999.9MVARh
0.1VARh
0.1kVARh
0.1MVARh

COS**
Cos** Resolution Accuracy (expressed in degrees)
0.20     0.01           0.2
0.50
0.80

HARMONICS
Range Max resolution Accuracy
DC - 25H     0.1V / 0.1A ¡¾(5% + 2 digit)
26H - 33H ¡¾(10% + 2 digit)
34H - 49H ¡¾(15% + 2 digit

¡á 2. GENERAL SPECIFICATIONS

Display
Type graphical with backlight
Resolution 128x128 (16384 pixel)
Pixel dimensions 0.5mmx0.5mm
Visible area 73mmx73mm

Functions
MEASUREMENT OF     
¡Ü star voltage and delta voltage
¡Ü phase current
¡Ü active, reactive and apparent power
¡Ü  active energy (Class 2 EN61036), reactive energy (Classe 3 IEC1268)
¡Ü  power factor and cosj (phase and total)
¡Ü  harmonics
¡Ü  voltage anomalies (breaks and spikes)
Maximum no. of selectable quantities: 64
Integration period: 5 ¢¬ 3600 sec.
Recording autonomy: more than 30 days with integration periods of 15 minutes
Memory: 2Mbyte
Environmental conditions
¡Ü Reference temperature 23¡Æ ¡¾ 5¡ÆC
¡Ü Working temperature 0¡Æ ¡À 40¡ÆC
¡Ü Relative humidity admitted < 70%
¡Ü Storage temperature -10 ¡À 60¡ÆC
¡Ü Storage humidity < 80%

Power supply
Internal power supply 6 batterie 1.5V serie AA LR6
Battery life about 50 hours
External power supply use only HT original one

Dimensions
¡Ü  225x165x105 mm

Weight
¡Ü ¡¤ about 800g including batteries

Complying with Standards
¡á SAFETY 
Safety of test instruments EN 61010-1
Insulation class 2
Pollution degree 2
  Overvoltage category CAT III 300V~, CAT II 350V~ (phase-earth),
CAT III 600V (phase-phase
Indoor use, max altitude 2000m 
¡á EMC 
  This instrument was designed in compliance with EMC Standards in force and its compatibilita has been tested with regard to EN61326-1 (1997) + A1 (1997). This instrument complies with 72/23/CEE and CEM 89/336/CEE (modified with 93/68/CEE)
¡á ELECTRICAL MEASUREMENTS 
Quality of voltage supplied by public utilities EN50160
Static electrical counters of active energy 
for AC current (class 2) EN61036
Static electrical counters of reactive energy 
for AC current (class 3) IEC1268
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§
°æ±âµµ ¼º³²½Ã Áß¿ø±¸ »ó´ë¿øµ¿ 513-15¹øÁö ¼±ÅØ½ÃÆ¼B/D 613È£ / ´ëÇ¥ ÀüÈ­ : 031-777-1588 / ÆÑ½º : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆÇ¸Å¾÷½Å°í ¼º³²½Ã Á¦2005-886È£ / ´ëÇ¥ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
Copyright ¨Ï 2002 (ÁÖ)ÄÚ¸°½º. All Rights Reserved.