DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 | |
| Humidity and Temperature Indicator with standard Temperature probe,also includes a calibration option |
Humidity
Measurement for Professionals
In addition to displaying the humidity and temperature readings, the
HMI41 can calculate dewpoint and wet bulb temperature, absolute humidity
and mixing ratio — no more awkward conversion tables or complex
calculations.
The indicator has an easy-to-read two-line liquid crystal display. The
display units (metric or non-metric) are easily selected.
Field Calibrator
The HMI41 indicator also includes a calibration option. The combination
of HMI41 indicator and HMP46 humidity and temperature probe is the best
choice for calibrating most humidity transmitters in the field at one
point quickly and easily. |
| |
|
Applications
|
- The
HMI41 hand-held indicator fitted with the HMP46 probe can be
used for spot checking humidity and temperature in
applications such as:
- Plant
Maintenance
- Installation
and inspection of air conditioning systems
- Production
and storage areas — freezers, cool stores and
containers
- Production
processes in temperatures of up to +180¡ÆC
- Monitoring
the drying of structures after water damages of during
construction
|
| |
|
SPECIFICATIONS
|
Indicator
|
| Maximum error of |
Humidity |
¡¾0.1%RH |
| indicator at +20 ¡ÆC |
Temperature |
¡¾0.1¡ÆC |
| Calculated
variables |
dewpoint
temperature, absolute humidity, wet bulb temperature, mixing ratio |
| Resolution |
0.1
%RH; 0.1¡ÆC |
| Power supply |
4
batteries, type IEC LR 6 |
| Battery operation
time |
72 h
continuous use with alkaline batteries |
| Operating
temperature |
-20 to
+60 ¡ÆC |
| Operating humidity |
non-condensing |
| Storage temperature |
-40 to
+70¡ÆC |
| Display |
two
line LCD |
| Weight (with
batteries) |
300 g |
| High
Temperature RH/Temp. Probe |
| Humidity |
| Measurement range |
0 to
100 %RH non-condensing |
| Maximum
accuracy |
0 to 90%RH |
¡¾1 %RH |
| 90 to 100%RH |
¡¾2 %RH |
| Typical long-term
stability |
better
than 1 %RH/a |
| Response time
(90%)at +20 ¡ÆC in still air |
15
seconds |
| Temperature |
| Measurement
range |
Continuous
measurement |
-40 to
+100¡ÆC |
| Short-term
measurement |
-40 to
+180¡ÆC |
| Accuracy at +20 ¡ÆC |
¡¾0.2
¡ÆC |
| Temperature sensor |
Pt 100
IEC 751 1/3 class B |
| Probe dimensions |
12 mm X
320 mm |
| Handle |
38 mm
X106 mm |
| General |
| Typical
ranges of calculated variables |
| |
dewpoint
temperature |
-40 to
+100 ¡ÆC |
| |
absolute humidity |
0
to 600 g/m3 |
| |
wet bulb
temperature |
0 to
+100 ¡ÆC |
| |
mixing ratio |
0
to 600 g/kg d.a. |
| Cable length |
1500 mm
- extended spiral cable |
| Operating
temperature range for electronics |
-20 to
+60 ¡ÆC |
| Probe head material |
stainless
steel |
| Housing
classification |
IP 65
(NEMA 4) |
| Sensor protection |
sintered
filter, part no. 0195 |
| Weight |
+50 g |
| Standard
Probe |
| Temperature |
-4 to
140 ¡ÆF (-20 to 60 ¡ÆC) |
| Accuracy |
¡¾0.15
¡ÆC |
| Humidity |
same as
high temp. probe |
| Dimensions |
18 mm X
118 mm overall length - 237 mm |
| CAT
NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| VA100381 |
|
HMI41/HMP45 |
|
HUMIDITY AND
TEMPERATURE INDICATOR WITH HMP45 STANDARD TEMPERATURE PROBE |
|
Yes |
|
1,941,840
|
| VA100380 |
|
HMI41/46 |
|
TEMPERATURE/HUMIDITY/DEWPOINT
INDICATOR WITH HMP46 HIGH TEMPERATURE STAINLESS STEEL PROBE |
|
Yes |
|
2,149,200
|
| VA100382 |
|
85-21797 |
|
OPTIONAL
CARRYING CASE HMI41/45 OR 46 PROBE/
FOR Temperature / Humidity / Dewpoint Indicator |
|
Yes |
|
106,920
|
| VA239603 |
|
HMK15 |
|
OPTIONAL
RH CALIBRATION KIT FOR
Temperature / Humidity / Dewpoint Indicator |
|
Yes |
|
1,293,840
|
| VA100384 |
|
85-180 |
|
OPTIONAL
REPLACEMENT SENSOR 85-HUMICAP 180 SENSOR
FOR Temperature / Humidity / Dewpoint Indicator |
|
Yes |
|
291,600
|
| VA100385 |
|
85-0195HM |
|
OPTIONAL
SINTERED FILTER, 133 MICRONS FOR 46 PROBE/
FOR Temperature / Humidity / Dewpoint Indicator |
|
Yes |
|
97,200
|
| |
|
|
 | |
 |
| ¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
 |
|
 |
|
|
 | |
 |
| ¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
 |
|
 |
|
|
 | |
|
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|
| |
| ȸ»ç¼Ò°³ | ¼ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ |
|
°æ±âµµ ¼º³²½Ã Áß¿ø±¸ »ó´ë¿øµ¿ 513-15¹øÁö ¼±ÅØ½ÃÆ¼B/D 613È£ / ´ëÇ¥ ÀüÈ : 031-777-1588 / ÆÑ½º : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆÇ¸Å¾÷½Å°í ¼º³²½Ã Á¦2005-886È£ / ´ëÇ¥ : È«¿µÈ / ¿î¿µÀÚ : À±»ó¹Ì
Copyright ¨Ï 2002 (ÁÖ)ÄÚ¸°½º. All Rights Reserved. |
|
|